Project experience Sewage treatment
System experience Vertical flow reedbeds
Services Design
Construction
Year completed 2014
Client Scottish Water
Contractor ARM Ltd
 
 

A major Scottish Water infrastructure development was undertaken in Cowdenbeath including the construction of two new Combined Sewer Overflows (CSOs) which collected additional surface water from within the town.

Challenge

Wastewater from Cowdenbeath had previously been treated at a wastewater treatment works (WWTW) on the south-east edge of the town, discharging into the Lochgelly Burn. As the town expanded, this WWTW became undersized and was converted to a pumping station passing flows forward to a larger works at Glenrothes. A holding tank of 1200m3 was retained for this purpose.

The increased flows generated by the new CSOs, totalling 229,700m3/annum, could not be managed by the pumping station or holding tank so a new treatment facility was required at the site to attenuate and treat the intermittent CSO flows prior to discharge into the Lochgelly Burn.

Scottish Water did not want to re-establish a full WWTW on the site and were therefore looking for a low-maintenance treatment solution which could handle intermittent flows and discharge, within consent, into the Lochgelly Burn. Modelled CSO flow and load data was provided for a nine-year period and provided a basis from which to generate design parameters (summarised in the PDF download).

Solution

The proposed site for the treatment solution was to the east of the pumping station on an old landfill site which covered mine workings. This meant that significant project costs would be linked to ground remediation, so minimising the size of the treatment solution would be critical.

Consequently an aerated vertical flow reed bed was the selected solution as this provides a high treatment capacity per unit area thus minimising the total land take. This was enhanced by making the bed much deeper than standard systems reducing the required treatment area further.

The data set was converted into cumulative summaries which determined that achieving complete treatment would not be cost effective as taking into account the highest flow outliers would greatly increase the size of the treatment area. The optimum treatment capability was concluded to be 79% of the annual BOD load, providing 95% overall compliance, and 100% of the ammonia load. The design solution was a two metre deep bed with a 4,000m2 process area which could treat 4000m3/d.

Flows are fed forward to the bed at a maximum rate of 46 l/s from a 3000m3 holding tank. On the occasions where flow rates exceed the storage capacity flows will spill to the Lochgelly Burn on the basis that they these will be rare events and the CSO will be significantly diluted.

Benefits

The aerated reed bed system has provided Scottish Water with an effective low maintenance treatment solution at Cowdenbeath avoiding the need to construct a new WWTW to handle the significantly increased flow of waste water generated by the new CSOs in Cowdenbeath. Compared to the alternatives the system has a lower TOTEX and aesthetically and ecologically enhances the landfill site.


A major Scottish Water infrastructure development was undertaken in Cowdenbeath including the construction of two new Combined Sewer Overflows (CSOs) which collected additional surface water from within the town.

Challenge

Wastewater from Cowdenbeath had previously been treated at a wastewater treatment works (WWTW) on the south-east edge of the town, discharging into the Lochgelly Burn. As the town expanded, this WWTW became undersized and was converted to a pumping station passing flows forward to a larger works at Glenrothes. A holding tank of 1200m3 was retained for this purpose.

The increased flows generated by the new CSOs, totalling 229,700m3/annum, could not be managed by the pumping station or holding tank so a new treatment facility was required at the site to attenuate and treat the intermittent CSO flows prior to discharge into the Lochgelly Burn.

Scottish Water did not want to re-establish a full WWTW on the site and were therefore looking for a low-maintenance treatment solution which could handle intermittent flows and discharge, within consent, into the Lochgelly Burn. Modelled CSO flow and load data was provided for a nine-year period and provided a basis from which to generate design parameters (summarised in the PDF download).

Solution

The proposed site for the treatment solution was to the east of the pumping station on an old landfill site which covered mine workings. This meant that significant project costs would be linked to ground remediation, so minimising the size of the treatment solution would be critical.

Consequently an aerated vertical flow reed bed was the selected solution as this provides a high treatment capacity per unit area thus minimising the total land take. This was enhanced by making the bed much deeper than standard systems reducing the required treatment area further.

The data set was converted into cumulative summaries which determined that achieving complete treatment would not be cost effective as taking into account the highest flow outliers would greatly increase the size of the treatment area. The optimum treatment capability was concluded to be 79% of the annual BOD load, providing 95% overall compliance, and 100% of the ammonia load. The design solution was a two metre deep bed with a 4,000m2 process area which could treat 4000m3/d.

Flows are fed forward to the bed at a maximum rate of 46 l/s from a 3000m3 holding tank. On the occasions where flow rates exceed the storage capacity flows will spill to the Lochgelly Burn on the basis that they these will be rare events and the CSO will be significantly diluted.

Benefits

The aerated reed bed system has provided Scottish Water with an effective low maintenance treatment solution at Cowdenbeath avoiding the need to construct a new WWTW to handle the significantly increased flow of waste water generated by the new CSOs in Cowdenbeath. Compared to the alternatives the system has a lower TOTEX and aesthetically and ecologically enhances the landfill site.


Interested in this project?
Call 01889 583811
OR
 
 
 
Downloads
  • Case study: Cowdenbeath CSO treatment
    Case study: Cowdenbeath CSO treatment
    2pp 3.17MB
    Download
  • Brochure - Vertical flow reed beds
    Brochure - Vertical flow reed beds
    2pp 217.52KB
    Download
  • Forced Bed Aeration™ technology
    Forced Bed Aeration™ technology
    2pp 347.3KB
    Download
 
 
 
Enquire
 


Related entries

  • ARM Ltd: A world first: combined sewer overflow with FBA
    A world first: combined sewer overflow with FBA
    ARM Ltd
    Policies set by the EU Water Framework Directive (WFD) mean stringent discharge consents have to be met including the treatment of wastewater from Combined Sewer Overflows (CSOs). CSOs take domestic sewage and storm water...
  • ARM Ltd: Reedbed asset assessment and support services
    Reedbed asset assessment and support services
    ARM Ltd
    Knowledge and proactive management of remote reedbeds is a key area where companies can cut operational and capital expenditure. The optimisation and enhancement of remote reedbed treatment systems can secure performance for...
  • ARM Ltd: Thames Water invests in FBA™ reed bed
    Thames Water invests in FBA™ reed bed
    ARM Ltd
    The UK’s largest water company has invested in a new reed bed system to help manage wastewater at its treatment facility in Uffington, Oxfordshire. Thames Water Limited appointed Rugeley-based reed bed specialists, ARM Reed...
Not found what you're looking for? View other options

Ask ARM Ltd about

Aerated vertical flow wetland for CSO effluent