Chemicals / parameters Ammonia
Water quality
Suitability Food / drink
Potable water
Process liquids
Raw water
Sludge / slurry / sewage
Type Fixed
Portable
Wall mounted
System type Analysers
Features Alarm trip
Datalogging
Self cleaning
Waterproof
Weatherproof
 
 
 

The ProAm ammonia monitor provides continuous measurement of ammoniacal-nitrogen using an ion selective gas sensing technique.

The instrument has wide diameter internal tubing and uses pinch valve technology to distribute fluids for analysis. Automatic calibration and chemical cleaning ensure reliable operation and self validation of measurement.

Applications

Ideally suited to low concentration measurement such as final effluent and raw water intake protection applications below 5.00 mg/L N but measurement range can be extended with sample dilution to 15,000mg/l N.

Filtration

The provision of membrane filtration, removing solids and biology above 0.45micron, ensures reliable operation even in challenging applications.

Sampling

Samples may be delivered to the instrument / panel filter or alternatively the membrane filtration may be mounted directly into the sample tank or chamber.

Installation

The instrumentation may be installed within an existing enclosure or PPM can provide secondary enclosures, complete with pre-installation to suit the application.


The ProAm ammonia monitor provides continuous measurement of ammoniacal-nitrogen using an ion selective gas sensing technique.

The instrument has wide diameter internal tubing and uses pinch valve technology to distribute fluids for analysis. Automatic calibration and chemical cleaning ensure reliable operation and self validation of measurement.

Applications

Ideally suited to low concentration measurement such as final effluent and raw water intake protection applications below 5.00 mg/L N but measurement range can be extended with sample dilution to 15,000mg/l N.

Filtration

The provision of membrane filtration, removing solids and biology above 0.45micron, ensures reliable operation even in challenging applications.

Sampling

Samples may be delivered to the instrument / panel filter or alternatively the membrane filtration may be mounted directly into the sample tank or chamber.

Installation

The instrumentation may be installed within an existing enclosure or PPM can provide secondary enclosures, complete with pre-installation to suit the application.


 
 
 
Downloads
  • ProAm ammonia analyser
    ProAm ammonia analyser
    2pp 80 KB
    Download
  • Case study: Wessex Water - continuous monitoring of effluent for ammonia
    Case study: Wessex Water - continuous monitoring of effluent for ammonia
    2pp 128K
    Download
  • PPM ISO 9001:2020 certificate
    PPM ISO 9001:2020 certificate
    1pp 1.14MB
    Download
  • Proam secondary encloures
    Proam secondary encloures
    2.11MB
    Download
  • Filtration & Sample Acquisition Literature
    Filtration & Sample Acquisition Literature
    3.82MB
    Download
  • Case Study Anglian Water selects Proam ammonia analyser technology
    Case Study Anglian Water selects Proam ammonia analyser technology
    3pp 4.69MB
    Download
  • Bespoke engineered systems
    Bespoke engineered systems
    3pp 25.4 MB
    Download
 
 
 
Enquire
 

Related entries

  • Pollution & Process Monitoring (PPM): Installation, commissioning & training - instrumentation
    Installation, commissioning & training - instrumentation
    Pollution & Process Monitoring (PPM)
    Pollution & Process Monitoring Ltd is a specialist manufacturer and supplier of water quality instrumentation. We support the products we manufacture and distribute in the UK with planned and emergency site attendance.
  • Pollution & Process Monitoring (PPM): Proam chloride monitor with auto-clean and calibration
    Proam chloride monitor with auto-clean and calibration
    Pollution & Process Monitoring (PPM)
    ProAm is an online analyser providing continuous or interval measurement of a water or wastewater sample. Typically the instrument is configured for ammonia measurement although other ion selective sensors are also available. The...
  • Pollution & Process Monitoring (PPM): Severn Trent Water installs Proam ammonia monitor
    Severn Trent Water installs Proam ammonia monitor
    Pollution & Process Monitoring (PPM)
    Following a rigorous field evaluation conducted by WRc, comparing the Proam ammonia monitor performance against a maintained site instrument, laboratory testing and comparison with six other manufacturer's instruments; the Proam...
  • Pollution & Process Monitoring (PPM): Final effluent ProAm ammonia monitoring at Wessex Water
    Final effluent ProAm ammonia monitoring at Wessex Water
    Pollution & Process Monitoring (PPM)
    The Poole WwTW site was initially selected to test the ProAm ammonia monitor on final effluent, over a two month test period in 2004. The trial was a success and Wessex Water decided to make the installation permanent. Since...

Also by Pollution & Process Monitoring (PPM)

Pollution & Process Monitoring (PPM) address and contact details

Pollution & Process Monitoring Limited
Bourne Enterprise Centre
Borough Green
Sevenoaks
TN15 8DG
Tel: 01732 882044
Fax: 01732 780190
View on map - 2 addresses
 
Follow Pollution & Process Monitoring (PPM)
 
Not found what you're looking for? View other options