Minicap FTC260 is a capacitive rod probe for point level detection in light bulk solids, designed for applications with aggressive media and heavy build-up. Suitable for materials such as grain products, flour, milk powder, animal feed, cement, chalk, or gypsum, with a grain size up to 30mm and dielectric constant er = 1.6.

  • Process temperature range: -40°C to +120°C; pressure range: -1 to 25 bar
  • Simple installation and commissioning without calibration required
  • Active build-up compensation ensures reliable operation in challenging conditions
  • No moving or wearing parts, supporting long operating life and mechanical safety
  • Sensor length: 140mm; process connection via threads
  • International explosion protection certificates and overfill prevention (WHG)
  • FDA-listed material for applications requiring compliance