Equipment Controllers
Functions Gas detection
Communication protocols Modbus
 
 

The TOCSIN 640 Addressable Detector Control Panel is a multi-channel detector controller.

The system can be used with any of the Tocsin Addressable range of detectors or I/O modules, to control up to 24 devices as gas detectors or I/O Modules.

Installation and operation

It is easy to install set up with wall and panel mount options are available. The rear enclosure can be rotated to accommodate top or bottom conduit entries. Alternately rear entries are available where cabling is buried into walls or other surfaces.

Features

  • Flexible power supply options
  • Three SPCO relays outputs as standard
  • 4-20mA output as standard
  • RS485 Modbus as standard
  • dedicated interlocks for E-stops and fire systems
  • LCD Display with multicolour backlight: flashes red on alarm, yellow on fault
  • E-Stop input (System Configurable)
  • Dedicated Interlock to fire systems (System Configurable)
  • Battery back-up option

Available sensor types

  • TOC-30 Series Safe Area Gas Detectors
  • TOCSIN 102 Infra Red Gas Detectors,TOCSIN 102 PhotoIonisation Gas Detectors
  • TOCSIN 102 Toxic and Oxygen Gas Detectors
  • TOCSIN 102 Thermal Conductivity Gas Detector
  • TOCSIN 103 Series Industrial Gas Detector
  • TOC 30 Annunciator Control Panel Accessory
  • TOCSIN 107 Addressable I/O Node Control Panel Accessory


The TOCSIN 640 Addressable Detector Control Panel is a multi-channel detector controller.

The system can be used with any of the Tocsin Addressable range of detectors or I/O modules, to control up to 24 devices as gas detectors or I/O Modules.

Installation and operation

It is easy to install set up with wall and panel mount options are available. The rear enclosure can be rotated to accommodate top or bottom conduit entries. Alternately rear entries are available where cabling is buried into walls or other surfaces.

Features

  • Flexible power supply options
  • Three SPCO relays outputs as standard
  • 4-20mA output as standard
  • RS485 Modbus as standard
  • dedicated interlocks for E-stops and fire systems
  • LCD Display with multicolour backlight: flashes red on alarm, yellow on fault
  • E-Stop input (System Configurable)
  • Dedicated Interlock to fire systems (System Configurable)
  • Battery back-up option

Available sensor types

  • TOC-30 Series Safe Area Gas Detectors
  • TOCSIN 102 Infra Red Gas Detectors,TOCSIN 102 PhotoIonisation Gas Detectors
  • TOCSIN 102 Toxic and Oxygen Gas Detectors
  • TOCSIN 102 Thermal Conductivity Gas Detector
  • TOCSIN 103 Series Industrial Gas Detector
  • TOC 30 Annunciator Control Panel Accessory
  • TOCSIN 107 Addressable I/O Node Control Panel Accessory


Industrial automation and control - products from other companies

Industrial automation and control - all companies