- Product name
- Leopold FilterWorx
- Applications
- Feedwater
- Potable water
- Wastewater / effluent
- Type
- Gravity sand filters
- Flow type
- Continuous flow
Leopold FilterWorx gravity media filtration system is designed for water and wastewater treatment, desalination pretreatment, and water reuse. Removes particulates, turbidity, organics, iron, manganese, and nutrients. Suitable for new or existing installations with multiple underdrain and media options.
- Gravity media filter for potable water, wastewater, desalination pretreatment, and biologically active filtration
- Removes particulates, turbidity, organics, iron, manganese, total suspended solids, ortho-phosphorus, nitrate, and silt
- Compatible with water-only, sequential air/water, and concurrent air/water backwash methods
- Works with flat bottom, front, centre, and H-flume types
- Automatic, manual, or semi-automatic control systems
- Choice of underdrains: Type XA, Type S, Type S Recycled Materials, Type SL
- Media options include silica sand, high density sand, anthracite, granular activated carbon, and expanded clay
- Meets AWWA, ASTM, and British DWI standards
Applications
- Potable drinking water treatment
- Tertiary wastewater treatment
- Nutrient removal in water or wastewater
- Reverse osmosis membrane desalination pretreatment
- Water reuse
- Biologically active filtration (BAF)
Materials
Media made from silica sand, high density sand, anthracite, granular activated carbon, expanded clay
Backwash troughs made from densely laminated fibreglass-reinforced plastic
Mounting brackets, hardware, and stabilisers made from stainless steel
Options and variations
Underdrain types: Type XA, Type S, Type S Recycled Materials, Type SL
Media support: graded gravel, I.M.S 200 media retainer, I.M.S 1000 media retainer
Trough types: fibreglass, stainless steel, with optional stainless steel media retention baffles
Valve actuators: electric, pneumatic, hydraulic
Control system: automatic, manual, semi-automatic
Performance
Removes particulates, turbidity, organics, iron, manganese, total suspended solids, ortho-phosphorus, nitrate, silt, TOC
Backwash methods: water only, sequential air followed by water, concurrent air/water, sustained air/water
Engineered filter media with uniformity coefficients below 1.30
Product accreditations
Conforms to AWWA, ASTM, and British DWI standards
Installation
Suitable for new or existing installations regardless of current underdrain type
Flat-bottom flume reduces excavation and support requirements
Maintenance
Backwash process designed to restore head loss and maximise filter runs while minimising power use and wastewater generation
Technical support
Engineering support for system analysis, evaluation, and design