Refine by
Channel
Showing best results - all illustrated entries. Change the channel to view specific categories.
Leak detection systems
(78)
Leak detection systems for industrial, commercial and utilities infrastructure. Sensing cables, probes and controllers for water, oil, chemical and refrigerant leaks. Monitoring for pipelines, storage tanks, bunds, plant rooms, roofs and data centres. Early warning, interstitial monitoring and compliance reporting. Integration with BMS and SCADA. Fixed, portable and networked solutions.
Leak detection systems - helping you find the best solution for your project.

UDOF-24 ‘Universal’ water in overflow pipe detector
UDOF-24 ‘Universal’ Overflow Detector is used to detect water in an overflow pipe. It requires a 24 volt power source. In the event of an alarm a volt-free contact is triggered, giving an alarm signal back to a BMS
Water leak detection systems
J.A.M. is expert at designing, manufacturing and installing water leak detection systems. A wide range of options is available to deliver effective solutions for specific building services requirements. Free project consultation and design advice with no obligation quotation service
Aqualarm CDBi-485 - water leak zone detector module
The Aqualarm CDBi-485 zone detector module is made of a purpose-moulded ABS box, housing the electronic circuitry. At one end of the module a locking line socket is fitted to enable connection of the detecting cable. The other end is fitted with glands for connection to the PCB. A red LED is incorporated in the top of the module
FLIR G304 optical gas imaging camera for refrigerant gases
FLIR G304 is an innovative optical gas imaging (OGI) camera used to detect possible hydrofluorocarbon, refrigerant and other industrial gas leaks. Designed with safety and efficiency in mind G304 can detect dangerous and environmentally harmful gases from safe distances. Capable of reducing inspection time by scanning large areas without
UDIN-24 Infrared Detector for non-conductive fluids
This UDIN-24 ‘Universal’ Point of use Infrared Detector requires a 24 volt power source, and in the event of an alarm a volt-free contact is triggered, giving an alarm signal back to a BMS etc: this detector does not require an i-Zone control panel; for use within Plant rooms and other solid floor areas; for the detection of oil, and all other
Aqualarm UDP-24 - universal point-of-use water detector
UDP-24 point-of-use water detector comprises two components: a detector module and a point detector connected together via a 1m jumper cable. It needs a 24 volt power source. In the event of an alarm a volt-free contact is triggered, giving an alarm signal back to a BMS etc. The Detector Module houses electronic circuitry; the Point Detector
FLIR gas detection cameras for the petrochemical industry
Many gases and chemical compounds are invisible to the naked eye, and strict regulations control how companies trace, document, rectify and report any leaks. The limitations of earlier probes and 'sniffer' technologies meant they could be inaccurate and time-consuming, and could expose inspectors to potential harm. Inspectahire supplies the FLIR
FLIR Si124 acoustic imaging camera for pressurised leaks
FLIR Si124 is an easy-to-use, stand-alone system for locating pressurised leaks in compressed air systems. Lightweight, one-handed solution is designed to help maintenance, manufacturing, and engineering professionals identify leaks up to 10 times faster than with traditional methods. Built with 124 microphones, the Si124 produces a precise
iZ-T25 - touchscreen control for multiple leak detectors
The iZ-T25 i-Zone touch screen control panel can simultaneously monitor all 25 Aqualarm detectors, including water, oils, chemicals, refrigerant gas leak detectors, and temperature and humidity detectors. Two pulsed flowmeters for incoming mains water can also be monitored, with the facility to control a solenoid valve. By connecting the control
QL320 optical gas imaging system for FLIR GFx320 and GF320
The QL320 is a quantitative optical gas imaging (QOGI) system that allows surveyors to measure the leak rates for methane and other hydrocarbons with immediate results, eliminating the need for secondary sampling. QL320 does not require close contact with the gas in order to measure emission rates, making it a safer solution for quantifying
STDi-24 - point of use conductive water detector
The STDi-24 point of use conductive water detector is designed for use in plant rooms and other solid floor areas. It has two components - the detector module and the point detector - connected by a 1m jumper cable. Conductive fluid touching the two detection pins simultaneously will cause the detector to enter an alarm condition. Alarm status and monitoring is via a network

FLIR GF346 optical gas imaging camera
FLIR GF346 thermal imaging camera is capable of detecting carbon monoxide leaks as well as a number of other gases. Capable of tracing leaks in real time through thermal imaging for efficient and precise identification of gas sources: real-time visualisation of gas leaks; can be used for a wide variety of thermal inspections; measures temperatures
OFDi-24 overflow detector – water in overflow pipes
The Aqualarm OFDi-24 overflow detector is made up of two components: the detector module and the overflow detector, connected via a 2m jumper cable. Both the detector module and overflow detector are manufactured from STAREX General ABS (SD-0150) plastic. The bottom of the overflow detector is fitted with a ¾” BSP threaded connector with two

UDC-24 ‘Universal’ Zone Detector Module for water leaks
The UDC-24 ‘Universal’ Zone Detector Module requires a 24-volt power source and, in the event of an alarm, a volt-free contact is triggered, giving an alarm signal back to a BMS. Does not require an i-Zone control panel; zone detector module for connection to detecting cable; manufactured from rust-proof and hard-wearing ABS plastic; LED and
FLIR G343 optical gas imaging (OGI) camera for CO2 leaks
FLIR G343, a member of the G-Series, is an innovative Optical Gas Imaging (OGI) camera used to visualise possible carbon dioxide (CO2) gas leaks. Whether or not CO2 is a byproduct of a production process or used as a trace gas, the G343 provides fast accurate detection to ensure safety. Advanced cooled 320 × 240 (76,800 pixels) resolution camera
OFDi-485 Overflow Detector
The Aqualarm OFDi-485 Overflow Detector is made up of TWO components, the Detector Module and the Overflow Detector, connected via a 2m jumper cable. Both the Detector Module and the overflow detector are manufactured from STAREX General ABS (SD-0150) plastic. The bottom of the Overflow Detector is fitted with a ¾” BSP threaded connector with two
FLIR GF343 optical gas imaging camera for CO2 detection
The GF343 is an optical gas imaging camera designed to detect CO2 leaks quickly, easily, and from a safe distance. Typical applications include detection of CO2 as a byproduct of a production process, as a trace gas used to detect leaks from power generators, or as part of an Enhanced Oil Recovery program. Visually detects CO2 gas leaks in real
IRDi-24 point of use infrared oil detector
The IRDi-24 point of use oil detector is made up of two components: the detector module and the point of use detector, connected together via a 1m jumper cable. Both the detector module and point of use detector are manufactured from STAREX General ABS (SD-0150) plastic. The detector module houses the electronic circuitry and the point of use

i-Zone Mini - 4-zone control panel for water leak detectors
The i-Zone Mini control panel can monitor up to four zones for water leak detection using cable, point, float or overflow detectors. The status of each detector is displayed on an LED monitor. Up to 100m of network cable per zone
Aqualarm IRDi-485 - point-of-use infrared oil detector
The Aqualarm IRDi-485 point-of-use oil detector comprises two components: the detector module and the point-of-use detector, connected via a 1m jumper cable. Both are manufactured from STAREX General ABS (SD-0150) plastic. The detector module houses the electronic circuitry; the point-of-use detector houses the infrared transmitter / receiver
Aqualarm ZLM-500 zoned cable monitoring for water leaks
The Aqualarm ZLM-500 zoned locating module is used to monitor combined leader / jumper and detecting cables for water leaks and cable damage. ZLM-500 is typically used for larger areas allowing monitoring per zone. It can monitor up to 500m of cables and allows users to locate the point of the alarm condition with an accuracy of ±1m, along with 'water detected' or 'open circuit' alarms

FLIR fixed installation thermographic monitoring cameras
Inspectahire offers a range of thermographic cameras for optical gas imaging, including the G300a, G300pt, and A6604. These systems are designed for continuous, 24/7 monitoring of gas pipelines and similar installations from a safe distance. Available for sale or rental
STDi-485 Point of use water detector
The STDi-485 Point of Use water Detector is comprised of TWO components, the detector module and the point detector, connected together via a 1m jumper cable. Both the Detector Module and the Point detector are manufactured from STAREX General ABS (SD-0150) plastic. The Detector Module houses the electronic circuitry and the Point Detector houses
Aqualarm FLi-485 - commercial liquid level float detector
The Aqualarm FLi-485 Liquid Level Detector is made up of two components, the detector module and the float switch, connected together via a 1m jumper cable. Both the detector module and the float switch are manufactured from STAREX General ABS (SD-0150) plastic. The glass filled nylon float switch is held in place by a sprung clip, secured to the

Sign up to receive the free ENVIROPRO bulletin
By signing up, you agree to our Terms and Conditions and Privacy Policy.
We won't share your email address with anyone without your consent. Bulletins are sent on a weekly basis. You can unsubscribe anytime.